<WSW54>
Selector No. | Function |
| Setting and Specifications | ||
|
|
|
|
| |
|
| No. 1 | 2 |
| |
1 | PictBridge command delay time | 0 0: 100 ms (default) | |||
0 | 1: 0 ms |
| |||
|
| ||||
2 | (Not used.) |
| |||
1 | 0: 50 ms |
| |||
|
| ||||
|
|
| |||
|
| 1 | 1: 200 ms |
| |
|
|
|
|
| |
3 | More CNG detection cycles in | 0: No | 1: 2 more cycles | ||
|
|
|
| ||
|
|
|
|
| |
4 | Cordless handset ID recovery | 0: Valid | 1: Invalid | ||
future (Not used.) | |||||
|
|
|
| ||
|
|
|
|
| |
|
| No. 5 | 6 |
| |
5 | Caller ID tone alert detection | 0 0: 10 ms (default) | |||
0 | 1: 20 ms |
| |||
|
| ||||
6 | time length |
| |||
1 | 0: 30 ms |
| |||
|
| ||||
|
|
| |||
|
| 1 | 1: 40 ms |
| |
|
|
|
| ||
7 | Caller ID wet pulse transmission | 0: Yes | 1: No | ||
| (default) |
| |||
|
|
|
| ||
|
|
|
| ||
8 | Switching between DTMF and | 0: DTMF | 1: FSK | ||
FSK for caller ID reception |
| (default) |
| ||
|
|
| |||
|
|
|
|
|
Note:
•Selectors 5 through 7 are applicable only to models designed for the UK market.
•Selector 8 is applicable only to models designed for the Chinese market.
•Selector 3: More CNG detection cycles in
If CNG detection fails even after adjustment of selectors 4 and 5 on WSW26, try adding 2 more cycles to the permitted number of CNG detection cycles.
•Selectors 5 and 6: Caller ID tone alert detection time length
In the event of a false detection of a caller ID tone alert, adjust the detection time length.
•Selector 7: Caller ID mild pulse transmission
If a caller ID (number display) cannot be displayed due to mild pulses transmitted after detection of tone alert, use this selector so as to make it impossible to transmit mild pulses.
•Selector 8: Switching between DTMF and FSK for caller ID reception
If a caller ID (number display) cannot be received, switch from DTMF to FSK. This operation can also be performed by means of the menu, by switching between DTMF and FSK.
App. | Confidential |