(11) General communications-related

Code 1

Code 2

Causes

 

 

 

 

 

 

B0

02

Unable to receive the next-page data.

 

 

 

B0

03

Unable to receive polling even during turn-around

transmission due to call reservation.

 

 

 

 

 

B0

04

PC interface error.

 

 

 

BF

01

Communication canceled by pressing the Stop/Exit

button before establishment of FAX communication*.

 

 

 

 

 

BF

02

Communication canceled by pressing the Stop/Exit

button after establishment of FAX communication*.

 

 

 

 

 

 

 

Transmission canceled due to a scanning error caused

BF

03

by no document or document feed problem in ADF

 

 

scanning in real time transmission.

 

 

 

*Establishment of FAX communication:

FAX communication is established when the calling station receives a DIS (reception capability) signal from the called station and the called station receives a NSS or DCS (communications test) signal from the calling station.

(12)Maintenance mode

 

Code 1

 

Code 2

Causes

 

 

 

 

 

 

 

 

 

 

 

E0

 

01

Failed to detect 1300 Hz signal in burn-in operation.

 

 

 

 

 

 

E0

 

02

Failed to detect PB signals in burn-in operation.

 

 

 

 

 

 

 

 

 

 

(13) Equipment error

 

 

 

 

 

 

 

Code 1

 

Code 2

Causes

 

 

 

 

 

 

FF

 

X X

Equipment error

 

 

(For X X, refer to "2.1 ERROR INDICATION")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-66