<WSW15>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

No. 1

2

 

 

1

 

0

0: 5 min.

Redial interval

0

1: 1 min.

2

 

1

0: 2 min.

 

 

 

 

1

1: 3 min.

 

 

 

 

 

 

 

 

No. 3

4

5

6

3

 

0

0

0

0: 16 times

 

0

0

0

1: 1 times

 

 

I

No. of redialings

0

0

1

0: 2 times

6

 

0

0

1

1: 3 times

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1: 15 times

 

 

 

 

 

 

7

(Not used.)

 

 

 

 

 

 

 

8

CRP option

0: Disable 1: Enable

 

 

 

 

 

 

Selectors 1 through 6: Redial interval and No. of redialings

The machine redials by the number of times set by selectors 3 through 6 at intervals set by selectors 1 and 2.

Selector 8: CRP option

If a command error occurs in the machine (calling station), the machine usually waits for three seconds and then makes a retry three times. This CRP option is a request command that can be sent from the called station for requesting the calling station to retry the failed command immediately.

App. 1-21

Confidential