<WSW10>
Selector No. | Function |
|
| Setting and Specifications | ||
|
|
|
|
| ||
|
|
|
|
| ||
1 | DPS switching interfacing with | 0: No | 1: Yes | |||
CML |
| |||||
|
|
|
|
| ||
|
|
|
|
| ||
2 | Time length from transmission of | 0: 100 ms | 1: 50 ms | |||
the last dial digit to CML ON | ||||||
|
|
|
| |||
|
|
|
|
| ||
3 | Time length from CML ON to | 0: 2 sec. | 1: 4 sec. | |||
CNG transmission |
| |||||
|
|
|
|
| ||
|
|
|
|
| ||
| Time length from CML ON to CED |
|
|
| ||
4 | transmission (except for facsimile- | 0: 0.5 sec. | 1: 2 sec. | |||
|
|
|
|
| ||
|
|
|
|
|
| |
|
|
| No. 5 | 6 |
| |
5 |
|
| 0 | 0: 1 time |
| |
No. of training retries |
| 0 | 1: 2 times |
| ||
6 |
|
| ||||
|
| 1 | 0: 3 times |
| ||
|
|
|
| |||
|
|
| 1 | 1: 4 times |
| |
|
|
|
|
| ||
7 | Encoding system | MR | 0: Allowed | 1: Not allowed | ||
|
|
|
|
| ||
8 | (Compression) | MMR | 0: Allowed | 1: Not allowed | ||
| ||||||
|
|
|
|
|
|
•Selector 2: Time length from transmission of the last dial digit to CML ON
This selector sets the time length from when the machine transmits the last dial digit until the CML relay comes on.
•Selector 3: Time length from CML ON to CNG transmission
This selector sets the time length until the machine transmits a CNG after it turns on the CML relay.
•Selector 4: Time length from CML ON to CED transmission
This selector sets the time length until the machine transmits a CED after it turns on the CML relay. This setting does not apply to switching between facsimile and telephone.
•Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
•Selectors 7 and 8: Encoding system (Compression)
This selector determines whether or not to allow the use of the MR/MMR coding system.