These errors are recoverable by following the message indicated on the LCD or following the items indicated in User Check.
■Error code 1E
Drum End Soon
Replacement time of the drum unit.
User Check
•Replace the drum unit with a new one.
■Error code 1F
Too Many Trays
Two or more optional trays are installed.
User Check
• Install one optional tray.
Step | Cause | Remedy |
|
|
|
1 | Connector: | Replace the connector: |
|
|
|
2 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
■Error code 24
Print Unable 24
Turn the power off and then back on again.
Internal temperature sensor failure
Step | Cause | Remedy |
|
|
|
|
|
|
| Harness connection failure of | Check the harness connection of the |
1 | internal temperature sensor | internal temperature sensor and reconnect |
|
| it. |
|
|
|
2 | Internal temperature sensor failure | Replace the internal temperature sensor. |
|
|
|
3 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|