3.2Error Code Cause and Remedy

These errors are recoverable by following the message indicated on the LCD or following the items indicated in User Check.

Error code 1E

Drum End Soon

Replacement time of the drum unit.

User Check

Replace the drum unit with a new one.

Error code 1F

Too Many Trays

Two or more optional trays are installed.

User Check

• Install one optional tray.

Step

Cause

Remedy

 

 

 

1

Connector: 54702-1219 failure

Replace the connector: 54702-1219.

 

 

 

2

Main PCB failure

Replace the main PCB ASSY.

 

 

 

Error code 24

Print Unable 24

Turn the power off and then back on again.

Internal temperature sensor failure

Step

Cause

Remedy

 

 

 

 

 

 

 

Harness connection failure of

Check the harness connection of the

1

internal temperature sensor

internal temperature sensor and reconnect

 

 

it.

 

 

 

2

Internal temperature sensor failure

Replace the internal temperature sensor.

 

 

 

3

Main PCB failure

Replace the main PCB ASSY.

 

 

 

3-12