•Selector 7: Standby position of the CCD unit
This selector determines whether the standby position of the CCD unit should be the home position or the location of the
•Selector 8: Line polarity reverse detection function
Line polarity will be reversed if the phone is hung up at the other end of the line. If this selector is set to "1," the machine will detect the reverse polarity during an answering machine operation and thereby determine that the phone has been hung up.
<WSW46>
Selector No. | Function |
| Setting and Specifications | ||
|
|
|
|
| |
|
|
|
|
| |
|
| No. 1 | 2 |
| |
1 |
| 0 | 0: Disable |
| |
Monitoring the PC ON/OFF | 0 | 1: Monitor SELECT IN | |||
2 | state | 1 | 0: Monitor STROBE | ||
|
| 1 | 1: Monitor both SELECT IN and | ||
|
|
| STROBE | ||
|
|
|
|
| |
3 | Parallel port output pins kept at | 0: Enable | 1: Disable | ||
high level (Not used.) | |||||
|
|
|
| ||
|
|
|
|
| |
4 | Previous filtering parameters for | 0: Enable | 1: Disable | ||
white level compensation | |||||
|
|
|
| ||
|
|
|
|
| |
5 |
|
|
|
|
INot used.
8
Note:
•Selector 4 is not applicable to models equipped with
•Selectors 1 and 2: Monitoring the PC ON/OFF state
For the related functions, refer to WSW36, selectors 2 and 3.
•Selector 4: Previous filtering parameters for white level compensation
At the start of scanning operation, the machine usually initializes white and black level data stored in the EEPROM by scanning the
Accordingly, incorrect white level data will be set up so that white vertical streaks will be brought on the scanning result.
Setting this selector to "0" (Enabled) will apply previously saved white level data instead of new incorrect compensation.
App. | Confidential |