■Black horizontal stripes
<User Check>
- Clean the inside of the machine and the corona wire in the drum unit.
- Replace the drum unit with a new one.
Step | Cause | Check | Result | Remedy | |
|
|
|
|
| |
|
|
|
|
| |
| Dirt on the | Are the electrodes on |
| Clean both electrodes. | |
1 | charged | the drum unit and | Yes | ||
| electrode | machine body dirty? |
|
| |
|
|
|
|
| |
| Paper tray | Is the paper tray ground |
| Correct bending of paper | |
| ground terminal | terminal bent, which is |
| tray ground terminal. | |
2 | provided in the | provided in the machine | Yes |
| |
| machine body | body? |
|
| |
|
| (Refer to Fig. |
|
| |
|
|
|
|
| |
| Toner attached | Are the horizontal stripes |
| This problem will disappear by | |
3 | on the develop | at 42.5 mm (develop | Yes | printing approximate 10 pages. | |
roller | roller circumference) | If the same problem occurs, | |||
|
| ||||
|
| intervals? |
| replace the toner cartridge. | |
|
|
|
|
| |
| Scratch and Dirt | Are the horizontal stripes |
| Replace the drum unit. | |
4 | on the exposure | at 94.2 mm (exposure | Yes |
| |
drum | drum circumference) |
| |||
|
|
| |||
|
| intervals? |
|
| |
|
|
|
|
| |
| Scratch and Dirt | Are the horizontal stripes |
| Replace the fuser unit. | |
5 | on the heat roller | at 78.5 mm (heat roller | Yes |
| |
|
| circumference) intervals? |
|
| |
|
|
|
|
| |
| HVPS PCB | Is the problem solved |
| Replace the HVPS PCB | |
6 | failure | after replacing the | Yes | ASSY. | |
|
| HVPS PCB ASSY? |
|
| |
|
|
|
|
| |
| Main PCB failure | Is the problem solved |
| Replace the main PCB | |
7 |
| after replacing the main | Yes | ASSY. | |
|
| PCB ASSY? |
|
| |
|
|
|
|
|
Bottom surface
of Paper tray
Paper tray ground terminal.
Fig.
Confidential |