Hitachi MP-96RD625-01 manual Temporary increase

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 122
Image 122

Data transfer speed

Data transfer speed of journal volumes

Data transfer speed

between the MCU and the RCU

Data transfer speed between hosts and the MCU

Time

Normal status

Temporary increase in

 

data to be transferred

Figure 3-31 Data Transfer Speed with URz (Data Transfer Speed of Journal Volumes)

As illustrated in Figure 3-31, the data transfer speed (i.e., the speed for reading and writing) of journal volumes in the master journal group must exceed the amount of temporary increase in data to be transferred. If the data transfer speed of journal volumes is below the amount of temporary increase in data to be transferred, the journal data for the temporary increase in data to be transferred will not be stored into journal volumes timely.

In Figure 3-31, data transfer speed between the primary storage system and the secondary storage system indicates transfer speed of journal data between the primary storage system and the secondary storage system.

Planning RAID Group Configuration and Journal Group Configuration

A RAID group can consist of physical volumes of different number of revolutions, physical volumes of different capacity, and physical volumes of different RAID configurations (e.g., RAID-1 and RAID-5). Data transfer speed of RAID groups is affected by physical volumes and RAID configurations.

3-56

Chapter 3 Preparing for Universal Replicator z/OS Operations

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 122
Image 122
Hitachi MP-96RD625-01 manual Temporary increase