Figure 5-3 Add DKC Window

The Add DKC window displays the following:

S/N: allows you to enter the five-digit serial number of the remote storage system.

LDKC: allows you to enter the LDKC number of the remote storage system. “00” is displayed when the remote storage system is TagmaStore USP/NSC. Note: The LDKC#01 cannot be used in this version.

Controller ID: allows you to enter the controller ID (model name that indicates the model) of the remote storage system.

Note: The controller ID for a USP V storage system is 5(USP V).

Path Gr. ID: allows you to enter the path group ID. Path group IDs are used for identifying groups of logical paths. One path group can contain up to eight logical paths.

Path group IDs are within the range of 1-FF (hexadecimal). If you select the Default check box, the default path group ID will be set.

Note: In the current version, you cannot enter path group IDs. Also, you cannot clear the Default check box. The number of path group IDs per one remote storage system is always 1.

M-R Path: allows you to specify logical paths from initiator ports on the local storage system to RCU target ports on the remote storage system.

Port: displays a list of initiator ports on the local storage system. Select an initiator port from this drop-down list.

Pair-Port: displays a list of all ports on the remote storage system. Select an RCU target port on the remote storage system from this drop-down list.

Note: When specifying a port, you can use the keyboard to enter the port number. When you enter the port number, you can abbreviate the port number into two characters. For example, you can enter 1A instead of CL1-A. You can use uppercase and lowercase letters.

Option: opens the DKC Option window.

Cancel: cancels the settings you made on the Add DKC window and then closes the window.

5-12

Chapter 5 Configuring Storage Systems and Logical Paths

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 182
Image 182
Hitachi MP-96RD625-01 manual Add DKC Window