![](/images/new-backgrounds/1167873/167873159x1.webp)
Setting up Remote Copy Connections
Figure 3-1 shows the remote copy connection configurations for URz operations. The primary storage system and secondary storage system of each URz pair must be connected via optical fiber cables. If you use multimode shortwave optical fiber cables, fibre cables up to 1.5 km in length and up to two switches are required for distances greater than 0.5 km. If you use single- mode long wave optical fiber cables, fibre cables up to 30 km in length and up to two switches are required for distances greater than 10 km. URz operations can be performed at distances of up to 30 km (18.6 miles) using standard single-mode long wave support. For further distance, the channel extender connections are required. URz operations can be performed at distances of up to 30 km (18.6 miles) using standard single-mode long wave support. For distances greater than 43 km (26.7 miles), approved channel extender products and telecommunications lines are required.
MCU/RCU
MCU/RCU
MCU/RCU
Shortwave: 0.5 km | Multimode shortwave optical fiber cables up to 0.5 km | |
RCU/MCU | Multimode longwave optical fiber cables up to 10 km | |
| ||
| Optical fiber cables | |
Shortwave: 1.5 km | Switch | |
RCU/MCU | Channel extender | |
ATM telecommunications line | ||
|
Max. 2 switches connection
Longwave: 10 km
RCU/MCU |
Longwave:30 km
MCU/RCU
RCU/MCU
Max. 2 switches connection
Unrestricted distance
MCU/RCU
RCU/MCU
Figure 3-1 URz Remote Copy Connection Configuration
The remote copy connection between primary storage system and secondary storage system provides three different configurations:
–Direct connection (see Figure
–Switch connection (see Figure
–Extender connection (see Figure
Chapter 3 Preparing for Universal Replicator z/OS Operations |