Hitachi MP-96RD625-01 manual Changing Options for a Data Volume Pair

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 252
Image 252

Changing Options for a Data Volume Pair

The Change Pair Option window allows you to change options for a pair of data volumes.

To change the pair options, follow the procedure below. Note that only the administrator of the primary storage system can perform the following operation. The administrator of the secondary storage system cannot perform the following operation:

1.Ensure that the Storage Navigator main window is in Modify mode.

For detailed information about how to do this, please refer to the Storage Navigator User's Guide.

2.Ensure that the Pair Operation window is displayed.

3.In the list, select and right-click the desired pair(s).

Caution: You can only change options for pairs in Duplex, or Suspend, Hold, or Hlde status. If you select a pair in another status, you cannot go on to the subsequent steps.

4.From the pop-up menu, select Change Pair Option. The Change Pair Option window appears (Figure 8-5).

5.In the Change Pair Option window, change pair options and select Set.

Note: If two or more pairs are selected in the list, the drop-down list on the window may display blank for option values. If you do not want to change the current option value for each of the pairs, ensure that the drop-down list displays blank. If you select a value other than blank from the drop- down list, the selected value will be set to each of the pairs.

6.See the Preview list in the Pair Operation window to check the settings that you have made.

If you want to modify a setting, select and right-click the setting and then select Modify.

If you want to cancel a setting, select and right-click the setting and then select Cancel.

7.Select Apply to apply the changes that you have made.

Note: If an error occurs, the rightmost column of the Preview list displays the error code. To view detailed information about the error, right-click the error code and then select Error Detail. An error message appears and gives you detailed information about the error.