Hitachi MP-96RD625-01 manual DKC Option Window

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 184
Image 184

Figure 5-4 DKC Option Window

The DKC Option window displays the following:

The Minimum Paths option specifies the minimum number of paths required for each remote storage system connected to the local storage system (default = 1).

Note: You cannot change the Minimum Paths for the current version.

The RIO MIH Time setting specifies the RIO MIH timer value, which is the wait time until data transfer from the local storage system to the remote storage system is complete. The RIO MIH time value must be from 10 to 100 seconds. The default setting is 15 seconds.

Note: RIO MIH is an acronym for remote I/O missing interrupt handler.

5-14

Chapter 5 Configuring Storage Systems and Logical Paths

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 184
Image 184
Hitachi MP-96RD625-01 manual DKC Option Window