Communication Time | This status indicates one of the following: | |
Out | • | A timeout error has occurred between the primary and the secondary storage |
| ||
|
| systems. |
| • | A logic error is detected between the primary and the secondary storage systems. |
|
| |
Resource Shortage | The local storage system rejected the function for configuring logical path connection. All | |
(Port) | logical path resources in the local storage system might be used for other connections. | |
|
| |
Resource Shortage | The remote storage system rejected the function for configuring logical path connection. All | |
logical path resources in the remote storage system might be used for other connections. | ||
|
| |
Serial Number | The serial number of the storage system connected to this logical path does not match the | |
Mismatch | serial number specified by the Add DKC window. | |
|
| |
Invalid Port | The port is not an initiator port. | |
|
| |
This status indicates one of the following: | ||
Mismatch | • | The specified port number is incorrect. |
| ||
| • | The port in the remote storage system is physically disconnected from the local |
|
| storage system. |
|
| |
The port on the remote storage system is not an RCU target port. | ||
Mismatch |
|
|
|
| |
Communication Failed | A communication timeout error has occurred on the path between the primary and the | |
| secondary storage systems. | |
|
|
|
Chapter 5 Configuring Storage Systems and Logical Paths |