Status Change by MCU(Suspend to Simplex): The status of the data volume pair was changed from Suspend to Simplex because of an operation from the primary storage system.

Status Change by MCU(Suspend to Pending): The status of the data volume pair was changed from Suspend to Pending because of an operation from the primary storage system.

Status Change by RCU(Suspend Pair Start): The status of the data volume pair was changed because an operation for splitting a pair started at the secondary storage system.

Status Change by RCU(Suspend Pair Complete): The status of the data volume pair was changed because an operation for splitting a pair finished at the secondary storage system.

Status Change by RCU(Suspend to Simplex; Delete Pair Start): An operation for releasing a pair has been started at the secondary storage system. The status of the data volume pair will change from Suspend to Simplex.

Status Change by RCU(Pending to Simplex; Delete Pair Start): An operation for releasing a pair has been started at the secondary storage system. The status of the data volume pair will change from Pending to Simplex.

Status Change by RCU(Duplex to Simplex; Delete Pair Start): An operation for releasing a pair has been started at the secondary storage system. The status of the data volume pair will change from Duplex to Simplex.

Status Change by RCU(Delete Pair Complete): The status of the data volume pair was changed because an operation for releasing a pair finished at the secondary storage system.

Ready for Delta resync: A data volume pair became ready for delta resync.

Ready for Delta resync(Failure): The failure occurred with the data volume pair which was ready for delta resync.

Status Change for Delta resync: The status of the primary data volume was changed to Hold because of a delta resync operation.

Status Change by MCU(Simplex to Hold): The status of the data volume pair was changed from Simplex to Hold because of an operation from the primary storage system.

Status Change by MCU(Hold to Duplex): The status of the data volume pair was changed from Hold to Duplex because of an operation from the primary storage system.

Status Change by MCU(Hold to Pending): The status of the data volume pair was changed from Hold to Pending because of an operation from the primary storage system.