Hitachi MP-96RD625-01 manual Troubleshooting

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 298
Image 298

 

Resource Shortage

The local and remote storage

Delete the failed path, and also delete all paths and remote

 

(Port)

system rejected the request

storage systems not currently in use. The local storage system

 

or,

for creating a logical path

can be connected to up to 64 remote storage systems with up

 

Resource Shortage

because all resources in the

to eight paths to each remote storage system.

 

local and remote storage

Make sure all local and remote storage system ports are properly

 

(Pair-Port)

 

systems are being used for

configured: ordinary target ports or RCU target ports for hosts, RCU

 

 

 

 

other connections.

target ports for remote storage systems, initiator ports for local

 

 

 

storage systems.

 

 

 

If necessary, connect to the remote storage system to delete paths

 

 

 

or remote storage systems and reconfigure ports, then reconnect to

 

 

 

the local storage system. After that, add the path or the remote

 

 

 

storage system again by using the Add Path window or the Add

 

 

 

DKC window.

 

 

 

 

 

Serial Number

The serial number (S/N) of

Make sure that you entered the correct remote storage

 

Mismatch

the remote storage system

system S/N and path parameters (e.g., local storage system

 

 

does not match the specified

port, remote storage system port, and controller ID). After

 

 

serial number (S/N).

that, delete the failed path. You may need to change the

 

 

 

minimum paths setting or delete the remote storage system

 

 

 

in order to delete the path. After deletion finishes, add the

 

 

 

path and the remote storage system again by using the Add

 

 

 

Path window or the Add DKC window.

 

 

 

Make sure that you entered the correct controller ID, and also make

 

 

 

sure that the topology settings of the local and remote storage

 

 

 

system ports are correct.

 

 

 

 

 

Invalid Port

The specified port is not

Make sure that the topology settings of the local and remote

 

 

configured as an RCP or

storage system ports are correct.

 

 

initiator port, or this path

Make sure that you entered the correct remote storage system S/N

 

 

already exists.

and path parameters (e.g., local storage system port, remote

 

 

 

storage system port, and controller ID). After that, delete the failed

 

 

 

path. You may need to change the minimum paths setting or delete

 

 

 

the remote storage system in order to delete the path. After deletion

 

 

 

finishes, add the path and the remote storage system again by

 

 

 

using the Add Path window and the Add DKC window.

 

 

 

 

 

<blank>

This path was not established.

Delete the failed path. You may need to change the minimum

 

 

 

paths setting or delete the remote storage system in order to

 

 

 

delete the path. After deletion finishes, add the path and the

 

 

 

remote storage system again by using the Add Path window

 

 

 

and the Add DKC window.

 

 

 

 

 

Pair-Port Number

The specified port in the

Make sure that you specified the correct remote storage

 

Mismatch

remote storage system is

system port. Correct the port number if necessary.

 

 

physically disconnected from

Make sure that the local storage system port and the remote

 

 

the local storage system.

storage system port are connected via cables to each other. If the

 

 

 

storage systems are not connected via cables, please connect them

 

 

 

via cables and then retry the operation.

 

 

 

Make sure that the topology settings of ports on the local and

 

 

 

remote storage systems are correct.

 

 

 

 

 

Pair-Port Type

The specified port in the

Make sure that the specified port in the remote storage

 

Mismatch

remote storage system is not

system is configured as an RCU target port. Configure the port

 

 

configured as an RCU Target

as an RCU target port if it is not configured that way.

 

 

port.

 

 

 

 

 

 

Communication

The local storage system is

Make sure that the remote storage system port and network

 

Failed.

connected to the remote

relay devices (e.g., cables and switches) are properly

 

 

storage system successfully,

configured and functioning.

 

 

but logical communication

 

 

 

timeout occurred.

 

 

 

 

 

4

 

Troubleshooting

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 298
Image 298
Hitachi MP-96RD625-01 manual Troubleshooting