Hitachi MP-96RD625-01 manual Logical Path Status, Status Remarks

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 188
Image 188

The DKC Status window displays the following:

List:

No.: displays serial numbers used for rows in the list

Path Status: indicates status of a logical path (For details, see Table 5-1)

Port: indicates a port on the local storage system

Pair-Port:indicates a port on the remote storage system.

S/N: indicates the serial number and LDKC number of the remote storage system.

Controller ID: displays the controller ID (model name that indicates the model) of the remote storage system.

Path Gr. ID: indicates a path group ID.

M-R Path: indicates the type of channel interface between the local and the remote storage systems. This column displays fibre.

Minimum Paths: Indicates the minimum possible number of paths between the local and the remote storage systems.

RIO MIH Time: indicates the RIO MIH timer value, which is the wait time until data transfer from the local storage system to the remote storage system is complete.

Note: RIO MIH is an acronym for remote I/O missing interrupt handler.

DKC Registered: Indicates the date and time when the local and the remote storage systems are associated to each other.

Last Updated: indicates the date and time when the last operation on a logical path to the remote storage system was performed.

Refresh the DKC Operation tab after this panel is closed: If you select this check box, information in the DKC Operation window will be refreshed after you close the DKC Status window.

Refresh: refreshes the information in the DKC Status window.

Close: closes the DKC Status window.

Table 5-1 Logical Path Status

Status

Remarks

 

Normal

 

This path has been successfully established and can be used for URz remote copy activities.

 

 

 

 

 

 

 

Nothing

 

An operation for configuring or deleting this logical path is in progress.

 

 

 

 

 

 

Initialization Failed

An error occurred with initialization of connection between the local and the remote storage

 

 

 

 

system. The probable causes are:

 

 

 

 

No cable is connected to the local storage system.

 

 

 

 

No cable is connected to the remote storage system.

 

 

 

 

No cable is connected to the network device that comes between the local and the remote

 

 

 

 

storage system.

 

 

 

 

 

 

5-18

 

Chapter 5 Configuring Storage Systems and Logical Paths

 

 

 

 

 

 

 

 

Hitachi Universal Replicator for IBM /OS User’s Guide

 

Page 188
Image 188