Port Number

The specified port number is

Mismatch

not correct, or the cable is not

 

connected to the specified

 

port.

 

 

Communication

A timeout error has occurred

Error

in the fibre path between the

 

local and remote storage

 

systems.

 

 

Logical Blockade

A failure occurs at a local

 

storage system port.

 

 

 

A failure occurs at a remote

 

storage system port.

 

 

 

A failure occurs in the path

 

relay equipment.

 

 

 

The connection cable is

 

physically broken.

 

 

Program Error

Program error is detected.

 

 

Delete the error path.

Check the specified port number or cable connections, and then retry the operation.

Delete the failed path and retry.

Repair the port status on the local storage system.

Repair the port status on the remote storage system. After that, delete the path by using the Delete Path or Delete DKC command, and then add the path and the remote storage system again by using the Add Path or Add DKC command.

Repair the path relay equipment. After that, delete the path by using the Delete Path or Delete DKC command, and then add the path and the remote storage system again by using the Add Path or Add DKC command.

Replace the broken cable. After that, delete the path by using the Delete Path or Delete DKC command, and then add the path and the remote storage system again by using the Add Path or Add DKC command.

Delete the path by using the Delete Path or Delete DKC command, and then add the path and the remote storage system again by using the Add Path or Add DKC command.

Table 11-3 Troubleshooting Suspended URz Pairs

Suspend

Type

Applies

to

Description

Corrective Action

Seconda

Primary

The user suspended the pair from the primary

Restore the pair from the primary

ry Data

data

or the secondary storage system by using the

storage system.

Volume

volume,

secondary data volume option.

 

by

secondar

 

 

Operator

y data

 

 

 

volume

 

 

 

 

 

 

by RCU

Primary

The primary storage system suspended a pair

Clear the error condition at the

 

data

because the primary storage system detected

secondary storage system or secondary

 

volume

an error condition at the secondary storage

data volume. If you need to access the

 

 

system.

secondary data volume, release the pair

 

 

 

from the secondary storage system. If

 

 

 

any data on the secondary data volume

 

 

 

has changed, release the pair from the

 

 

 

primary storage system and then re-

 

 

 

create the pair (Add Pair). If data on the

 

 

 

secondary data volume has not

 

 

 

changed, restore the pair from the

 

 

 

primary storage system.

 

 

 

 

Troubleshooting

5

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 299
Image 299
Hitachi MP-96RD625-01 manual Troubleshooting Suspended URz Pairs, Suspend Type Applies Description Corrective Action