Hitachi MP-96RD625-01 manual Hardware Configuration, Setup Procedure

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 103
Image 103

Hardware Configuration

This section explains hardware configuration for a 3DC cascading configuration using TCz Synchronous and UR-z/OS®. In a 3DC cascading configuration, three USP V storage systems are required. It is recommended that Business Continuity Manager is installed on hosts in the primary site, the intermediate site, and the secondary site. Storage Navigator computers are required for these sites. The following explains hardware configuration for these sites.

Primary site

The USP V storage system must have TCz Synchronous installed.

The USP V storage system must have TCz Synchronous M-VOL.

Storage system settings must be made so that Business Continuity Manager can be used. For detailed information about settings required for using volumes in a remote site, please refer to Business Continuity Manager User's Guide.

Intermediate site

The USP V storage system must have TCz Synchronous installed.

The USP V storage system must have URz installed.

The USP V storage system must have a volume used as both a TCz Synchronous R-VOL and a URz primary data volume.

The USP V storage system must have a URz master journal volume.

Storage system settings must be made so that Business Continuity Manager can be used. For detailed information about settings required for using volumes in a remote site, please refer to Business Continuity Manager User's Guide.

Remote site

The USP V storage system must have URz installed.

The USP V storage system must have a URz secondary data volume.

The USP V storage system must have a URz restore journal volume.

Storage system settings must be made so that Business Continuity Manager can be used. For detailed information about settings required for using volumes in a remote site, please refer to Business Continuity Manager User's Guide.

Setup Procedure

This section explains the procedure for setting up a 3DC cascading configuration using TCz Synchronous and URz.

To set up a 3DC cascading configuration:

1. Install TCz Synchronous and URz. Configure ports and journal groups.

Chapter 3 Preparing for Universal Replicator z/OS Operations

3-37

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 103
Image 103