6.Select Apply to apply the settings.

Note: If an error occurs, the rightmost column of the Preview list displays the error code. To view detailed information about the error, right-click the error code and then select Error Detail. An error message appears and gives you detailed information about the error.

Figure 6-5 Change JNL Option Window

The Change JNL Option window displays the following:

Inflow Control: Allows you to specify whether to restrict inflow of update I/Os to the journal volume (in other words, whether to slow delay response to hosts).

Yes indicates inflow will be restricted. No indicates inflow will not be restricted.

Note: If Yes is selected and the metadata or the journal data is full, the update I/Os may stop.

Data Overflow Watch: Allows you to specify the time (in seconds) for monitoring whether metadata and journal data are full. This value must be within the range of 0 to 600 seconds.

Note: If Inflow Control is No, Data Overflow Watch does not take effect and does not display anything.

Copy Pace: Allows you to specify the pace (speed) for an initial copy activity for one volume. The default is Low.

Low: The speed of the initial copy activity is slower than Medium and High.

Chapter 6 Configuring Journal Groups

6-17

Hitachi Universal Replicator for IBM /OS User’s Guide