Hitachi MP-96RD625-01 Suspend Types, Consistency Status for Suspended URz Secondary Data, Volumes

Models: MP-96RD625-01

1 314
Download 314 pages 57.88 Kb
Page 59
Image 59

Table 2-5

Suspend Types

 

 

 

Suspend Type

Applies to

Description

 

 

 

Secondary

Primary data

The user suspended the pair from the primary storage system or

data volume

volume, secondary

secondary storage system using the secondary data volume option.

by operator

data volume

 

 

 

 

By MCU

Secondary data

The secondary storage system received a request from the primary storage

 

volume

system to suspend the volume pair. The primary data volume suspend

 

 

type is Primary data volume by Operator or Secondary data volume by

 

 

Operator.

 

 

 

By RCU

Primary data

The primary storage system detected an error condition at the secondary

 

volume

storage system which caused the primary storage system to suspend the

 

 

URz volume pair. The secondary data volume suspend type is By MCU.

 

 

 

Delete Pair to

Primary data

The primary storage system detected that the secondary data volume

RCU

volume

status changed to simplex because the user released the pair from the

 

 

secondary storage system. The pair cannot be resumed because the

 

 

secondary data volume does not have the suspended status.

 

 

 

Secondary

Primary data

The primary storage system detected an error during communication with

Data Volume

volume

the secondary storage system or an I/O error during update copy. In this

Failure

 

case, the secondary data volume suspend type is usually By MCU.

 

 

 

MCU IMPL

Primary data

The primary storage system could not find valid control information in its

 

volume, secondary

nonvolatile memory during the IMPL procedure. This condition occurs only

 

data volume

if the primary storage system is completely without power for more than

 

 

48 hours (e.g., power failure and fully discharged backup batteries).

 

 

 

Initial Copy

Primary data

The volume pair was suspended before the initial copy operation was

failed

volume, secondary

complete. The data on the secondary data volume is not identical to the

 

data volume

data on the primary data volume.

 

 

 

JNL Cache

Primary data

The data volume pair was suspended because it was highly likely that

Overflow

volume, secondary

journal data will overflow.

 

data volume

 

 

 

 

MCU P/S OFF

Secondary data

The primary storage system is powered off.

 

volume

 

 

 

 

Table 2-6

Consistency Status for Suspended URz Secondary Data

 

Volumes

 

Consistency Status

Volume

Description

This URz volume pair was suspended alone. Update sequence consistency between this secondary data volume and other secondary data volumes in this journal group is not ensured. This secondary data volume cannot be used for disaster recovery at the secondary system. This status is indicated when:

This volume pair was suspended by a user-initiated suspend pair operation with the URz Suspend option set to Volume.

This volume pair was suspended due to a failure that did not affect the entire consistency group, and the Error Level pair option for this pair is set to Volume.

Chapter 2 About Universal Replicator Operations

2-37

Hitachi Universal Replicator for IBM /OS User’s Guide

Page 59
Image 59
Hitachi MP-96RD625-01 Suspend Types, Consistency Status for Suspended URz Secondary Data, Volumes, Applies to Description