If you specify P1 and P2 beyond the PCL Picture Frame, your drawing

 

is scaled with respect to those locations; however, only the portion of

 

the drawing fitting within the effective window is drawn.

 

 

Note

The specified P1/P2 percentages are converted to the equivalent

 

plotter unit coordinates. If the coordinate system orientation

 

subsequently changes (for example, by sending an RO command),

 

the plotter unit position is maintained with respect to the new

 

orientation. If an IP command without parameters is executed after

 

the axes have been rotated with the RO command, P1 and P2

 

locations change to reflect the rotation.

 

The locations of P1 and P2 interact with the following commands:

 

Table 19-13 Commands Affected by P1/P2

Command

Group

 

 

IW, Input Window

The Configuration/Status Group

RO, Rotate Coordinate System

 

SC, Scale

 

 

 

FT, Fill Type

The Line and Fill Attributes Group

LT, Line Type

 

PW, Pen Width

 

WU, Pen Width Unit Selection

 

 

 

DR, Relative Direction

The Character Group

LB, Label

 

SR, Relative Character Size

 

 

 

An IR command remains in effect until another IR command is executed, an IP command is executed, or the printer is initialized.

19-28The Configuration and Status Group

EN

Page 442
Image 442