AT Command

Value

Parameter

 

 

 

ATS0=

0

0=AUTOANSWER off

 

 

(default)

 

 

 

 

1

1=AUTOANSWER on

 

 

 

ATS2=

43

ASCII code for escape

 

 

sequence character

 

 

 

ATS3=

13

Code for CR

 

 

 

ATS4=

10

Code for LF

 

 

 

ATS5=

8

Code for BS

 

 

 

ATS12=

100

Time interval for escape

 

 

sequence

 

 

 

ATS30=

 

Error Level:

 

 

 

 

0

No AT command; syntax,

 

 

illegal register value,

 

 

command not executed

 

 

 

 

1

Unknown command

 

 

parameter

 

 

 

 

2

Unknown command

 

 

 

ATS31=

0

Protocol: X.75 (default)

 

 

 

 

1

Protocol: HDLC

 

 

 

 

2

Protocol: V.110

 

 

 

 

3

Fax Group 3

 

 

 

 

4

Protocol: TEL

 

 

 

 

5

Protocol: X.25

 

 

 

 

7

Protocol: V.120

 

 

 

 

8

Protocol: Analog Modem

 

 

(V.32bis)

 

 

 

ATS35=

14400

Baud rate

 

 

 

ATS36=

0

Parity: none (default)

 

 

 

 

1

odd

 

 

 

 

2

even

 

 

 

ATS37=

0

Stopbits: 1 bit (default)

 

 

 

 

1

2 bits

 

 

 

ATS38=

0

Data bits: 8 (default)

 

 

 

 

1

Data bits: 7

 

 

 

190IBM ISDN PC Card:User’s Guide