All RSL signals are routed adjacent to a ground reference plane. This includes all signals from the last RIMM to the termination. If signals are routed on the bottom from the last RIMM to the termination, the ground reference plane on the 3rd layer must extend under these signals and include the ground side of the VTERM decoupling capacitors.
CTABs must not cross (or be on top of) power plane splits. They must be entirely referenced to ground.
At least 10 mils of ground flood isolation is required around all RSL signals. (Ground isolation must be exactly 6 mils from RSL signals.) Ground flood is recommended for isolation. This ground flood should be as close as possible to the MCH (and the first RIMM). If possible, connect the flood to the ground balls/pins on the MCH/connector.
•Clean VREF routing
Ensure a 1 ⋅ 0.1 ∝ F capacitor on VREF at each connector.
Use a 10
Do not route VREF near
•RSL routing
All signals must be
table in the Intel® 820 Chipset Family: 82820 Memory Controller Hub (MCH) Datasheet to verify the trace lengths.) Ensure that signals with a dummy via are compensated correctly.
ALL RSL signals must have one via near the MCH BGA pad. Signals routed on the secondary side of the MB will have a “real via,” while signals routed on the primary side will have a “dummy via.” Additionally, all signals with a dummy via must have an additional trace length of 25 mils.
Signals must “alternate” layers, as shown in the following table:
If Signal Routed from MCH | Then Route Signal from 1st RIMM |
to 1st RIMM on: | to Next RIMM on: |
|
|
Primary side | Secondary side |
|
|
Secondary side | Primary side |
|
|
•Clock routing
Clock signals must be routed as a differential pair. The traces must be 14 mils wide and 6 mils apart (with no ground isolation) when they are routed as a differential pair. For very short sections under the MCH and under the first RIMM, it will not be possible to route as a differential pair. In these sections, the clocks signals must neck up to 18 mils and be ground- isolated with at least 10 mils ground isolation.
Clock signals must be
When clock signals serpentine, they must serpentine together (to maintain differential 14:6 routing).
22 mil ground isolation is required on each side of the differential pair.
Design Guide | 59 |