Figure 66. LOM/CNR Interconnect

ICH2

A

Res. pack

B

C

PLC

D

CNR

PLC card

IO_subsys_LOM-CNR_intercomm

Table 23. Length Requirements for Figure 66

Configuration

A

B

C

D

 

 

 

 

 

Intel® 82562EH

0.5” to 6”

4” to (10” – A)

 

 

Intel® 82562ET

0.5” to 7”

3” to (10” – A)

 

 

Dual footprint

0.5” to 6.5”

3.5” to (10” – A)

 

 

 

 

 

 

 

Intel® 82562ET/EH card (see

0.5” to 6.5”

 

2.5” to (9” – A)

0.5” to 3”

Note)

 

 

 

 

 

 

 

 

 

Note: The total trace length should not exceed 13 inches.

Additional guidelines for this configuration are as follows:

Stubs due to the resistor pack should not be present on the interface.

• The resistor pack value can be 0 Ω or 22 Ω .

LAN-on-motherboard PLC can have a dual-footprint configuration.

2.22.1.4.Signal Routing and Layout

LAN connect signals must be carefully routed on the motherboard, to meet the timing and signal quality requirements of this interface specification. The following are general guidelines that should be followed. It is recommended that the board designer simulate the board routing, to verify that the specifications are met for flight times and skews resulting from trace mismatch and crosstalk. On the motherboard, the length of each data trace is either equal to or up to 0.5 inch shorter than the LAN_CLK trace. (LAN_CLK should always be the longest motherboard trace in each group.) See Figure 67.