Chapter 2

File – Import – Digitizer – Step Scan (When VIVID 700 is Selected)

Performing Step Scan with the VIVID 700

This command is used to take two or more shots using the optional rotating stage via the remote control function of this software. If a rotating stage has been selected by the rotating table, rotation of the stage can also be controlled.

After the necessary shots are taken, scan the calibration chart. Data acquired from different angles will be subjected to registration, and the resulting data will appear.

Warning

Never stare into the laser emitting window.

Do not place a lens, mirror or optical element in the passage of the laser beam. Doing so may converge the laser beam, resulting in damage to your eyes, burns or fire. To prevent the above accidents, make sure that a wall or similar which can block the laser beam is located behind the object.

File

Menu

Note

If the rotating stage does not operate correctly from the dialog box, turn OFF the stage, turn it ON again, and then try to operate it.

Memo

The calibration chart is an accessory of the rotating stage set.

Before performing the procedure below, make sure that the digitizer you are going to use is selected by the File

– Select Digitizer command.

Ref. For details of the File – Select Digitizer command, refer to page 144.

Operating Procedure

1 From the [File] menu, select [Import], [Digitizer] and then [Step Scan].

The [File-Import-Digitizer-Step Scan] dialog box will appear.

2 Place the object on the rotating stage.

3 Select the desired rotation step from “90”, “60” and “Other”. The rotating stage will rotate at the selected step.

If “Other” is selected, enter the desired rotation angle.

4 Move the Zoom bar to set the desired view angle.

700A new color image captured from the speci- fied view angle will appear. (No color image will appear if the [Auto read] checkbox is un- checked.)

The color monitor image currently captured by the VIVID 700 will appear in the “Color” area of the dialog box. (No color image will appear if the

[Auto read] checkbox is unchecked even if the [Option] checkbox is checked.)

106