File – Import – Digitizer – One Scan (When VIVID 9i is Selected)

Chapter 2

File

Menu

9i

Parameters for [File-Import-Digitizer-One Scan-Option] Dialog Box

Scan Parameter

 

Mode

• Standard:The Filter settings are fixed to H.Q. & N.F.

 

 

 

The settable distance range is from 600 to 1,000 mm.

 

 

 

The Gain value is fixed at 0.

 

 

• Extend: The Filter settings are fixed to Noise Filter (N.F.).

 

 

 

The settable distance range is from 500 to 2,500 mm.

 

 

• User:

The Filter settings can be user-defined.

 

 

 

The settable distance range is from 500 to 2,500 mm.

 

 

 

 

 

Digitizer’s Parameter

• GET:

Loads the setting parameters from VIVID 9i and uses them as parameters for this

 

 

 

command.

 

 

 

• SET:

Saves the parameters set by this command to VIVID 9i as the setting parameters.

 

 

 

 

Number of Scans

Sets the number of shots to expand the dynamic range.

 

 

Increasing the number of shots reduces data loss.

 

 

 

 

Brightness

Checking this checkbox enables you to set the brightness of the image.

 

 

 

 

Use Color

Checking this checkbox takes a color shot when a scan is made.

 

 

 

 

Log

Performs log correction for the color data if this checkbox is checked. This correction is used to

 

 

make neutral colors brighter.

 

 

 

 

Dark

Performs dark correction for the color data if this checkbox is checked. This correction is used

 

 

when lines are noticeable in the color image.

 

 

 

 

 

 

Convert Parameter

 

 

 

 

 

 

 

Save Raw Data

Checking this checkbox displays the data save dialog at the end of the File-Import-Digitizer-

 

 

One Scan command, allowing you to save the data.

 

 

 

 

Reduction Rate

Used to select the number of data points to be read from “1/1”, “1/4”, “1/9”, “1/16” and “Adaptive”.

 

 

 

 

 

 

Filter

• None:

 

Performs no correction for points when reading data. This can be set for

 

 

 

 

User mode only.

 

 

• Noise Filter(N.F.):

Reduces noise in points when reading data.

 

 

• High Quarity(H.Q.):

Deletes low-reliable data when reading data.

 

 

• H.Q. & N.F.:

Reduces noise in points and deletes low-reliable data when reading data.

 

 

Note

 

 

 

 

In the case of low-reliable data, areas with excessively high laser power are displayed in light gray, and

 

 

those with excessively low laser power are displayed in dark gray.

 

 

 

 

Fill Holes

If “ON” is selected, points are generated in the holes that were produced as a loss of data so that

 

 

the holes are filled.

 

 

 

 

 

Remove

Select the data to be deleted when reading data.

 

 

• None:

 

Outputs the data without performing specific processing.

 

 

• Boundary (B.):

Outputs the data after deleting boundary points.

 

 

• 5deg & B./10dwg & B./15deg. & B./20deg & B.:

 

 

 

 

Outputs the data after deleting the points present inside and at the bound-

 

 

 

 

ary of the polygons that are angled within approximately 5, 10, 15 and 20

 

 

 

 

degrees to the vector of the line of view.

 

 

 

 

Stage Parameter

Select the Port and Model to be used and click on the [Apply] button. The rotary stage will be

 

 

initialized. If initialization is successful, the rotary stage can be controlled by using the Angle

 

 

slide bar in the [File-Import-Digitizer-One Scan] dialog box.

 

 

 

 

Default

Restores the default parameter settings.

 

 

 

 

OK

Closes the [File-Import-Digitizer-One Scan-Option] dialog box.

 

 

The settings will be set.

 

 

 

 

Cancel

Closes the [File-Import-Digitizer-One Scan-Option] dialog box.

 

 

The settings will be cancelled.

 

 

 

 

 