File – Import – Digitizer – One Scan (When VIVID 910 is Selected)
Parameters for
Scan Parameter
| Mode | • Select the scanning mode : FINE or FAST | |
|
|
| |
| Scan Parameter | • Load : Loads the setting parameters and uses them as parameters for this command. | |
|
| • Save : Saves the parameters set by this command as the setting parameters. | |
|
|
| |
| Brightness | Checking this checkbox enables you to set the brightness of the image. | |
|
|
| |
| Use Color | Checking this checkbox takes a color shot when a scan is made. | |
|
|
| |
| Log | Performs log correction for the color data if this checkbox is checked. This correction is used to | |
|
| make neutral colors brighter. | |
|
|
| |
| Dark | Performs dark correction for the color data if this checkbox is checked. This correction is used | |
|
| when lines are noticeable in the color image. | |
|
|
|
|
| Convert Parameter |
|
|
|
|
| |
| Save Raw Data | Checking this checkbox displays the data save dialog at the end of the | |
|
| One Scan command, allowing you to save the data. | |
|
|
| |
| Reduction Rate | Used to select the number of data points to be read from “1/1”, “1/4”, “1/9”, “1/16” and “No Poly- | |
|
| gon”. |
|
|
|
|
|
| Filter | • None : | Performs no correction for points when reading data. |
|
| • Noise Filter(N.F.) : Reduces noise in points when reading data. | |
|
| • High Quarity(H.Q.) : Deletes | |
|
| • H.Q. & N.F. : | Reduces noise in points and deletes |
|
|
| |
| Fill Holes | If “ON” is selected, points are generated in the holes that were produced as a loss of data so that | |
|
| the holes are filled. |
|
|
|
| |
| Remove | Select the data to be deleted when reading data. | |
|
| • None : | Outputs the data without performing specific processing. |
|
| • Boundary (B.) : | Outputs the data after deleting boundary points. |
|
| • 5deg & B./10dwg & B./15deg. & B./20deg & B. : | |
|
|
| Outputs the data after deleting the points present inside and at the bound- |
|
|
| ary of the polygons that are angled within approximately 5, 10, 15 and 20 |
|
|
| degrees to the vector of the line of view. |
|
|
|
|
| Hardware Parameter | • Vertical : | Check this checkbox if using the VIVID unit in vertical orientation. |
|
| • Horizontal : | Check this checkbox if using the VIVID unit in horizontal orientation. |
|
|
| |
| Stage Parameter | Select the Port and Model to be used and click on the [Apply] button. The rotary stage will be | |
|
| initialized. If initialization is successful, the rotary stage can be controlled by using the Angle | |
|
| slide bar in the | |
|
|
| |
| Default | Restores the default parameter settings. | |
|
|
| |
| OK | Closes the | |
|
| The settings will be set. | |
|
|
| |
| Cancel | Closes the | |
|
| The settings will be cancelled. | |
|
|
|
|
Chapter 2
File
Menu
910
57