File – Import – Digitizer – Step Scan (When VIVID 300 is Selected)
Performing Step Scan with the VIVID 300
This command is used to take two or more shots using the optional rotating stage via the remote control function of this software. If a rotating stage has been selected by the Turntable, rotation of the stage can also be controlled.
After the necessary shots are taken, scan the calibration chart. Data acquired from different angles will be subjected to registration, and the resulting data will appear.
Warning
Never stare into the laser emitting window.
Do not place a lens, mirror or optical element in the passage of the laser beam. Doing so may converge the laser beam, resulting in damage to your eyes, burns or fire. To prevent the above accidents, make sure that a wall or similar which can block the laser beam is located behind the object.
Chapter 2
Note
If the rotating stage does not operate correctly from the dialog box, turn OFF the stage, turn it ON again, and then try to operate it.
Memo
•The calibration chart is an accessory of the rotating stage set.
•Before performing the procedure below, make sure that the digitizer you are going to use is selected by the File
– Select Digitizer command.
Ref. For details of the File – Select Digitizer command, refer to page 144.
File
Menu
Operating Procedure
1 | From the [File] menu, select [Import], | • The color monitor image currently captured by |
| [Digitizer] and then [Step Scan]. | the VIVID 300 will appear in the “Color” area of |
| The | the dialog box. (No color image will appear if the |
| box will appear. | [Auto read] checkbox is unchecked even if the |
|
| [Option] checkbox is checked.) |
2 Place the object on the rotating stage.
3 Select the desired rotation step from “90”, “60” and “Other”. The rotating stage will rotate at the selected step.
If “Other” is selected, enter the desired rotation angle.