File – Import – Digitizer – One Scan (When VIVID 900/910 is Selected)
Chapter 2
File
Menu
Parameters for
Hardware Tab
| Auto SCSI ID |
| Check this checkbox if you want the program to automatically check SCSI connections for VIVID | |
|
|
| units. If this checkbox is not checked, the program will recognize VIVID units at specified SCSI IDs | |
|
|
| only. |
|
| Mounted |
| • Vertical : | Check this checkbox if using the VIVID unit in vertical orientation. |
|
|
| • Horizontal : Check this checkbox if using the VIVID unit in horizontal orientation. | |
|
|
|
| |
| Apply |
| When you click the [Apply] button after selecting the serial port and rotating stage, the [Angle] | |
|
|
| slidebar becomes effective and stage control is enabled. | |
|
|
| Note |
|
|
|
| If connecting to a | |
|
|
| ing to a | |
| Angle |
| This slidebar becomes enabled when the program determines that the rotating stage is operating | |
|
|
| normally. You can use the slidebar to control the stage’s rotation. | |
|
|
|
|
|
| Parameters for | |||
|
|
|
| |
| Reduction Rate |
| Selects the reduction rate to be applied when importing the data. | |
|
|
| You can select any of the following: “1/1”, “1/4”, “1/9”, “1/16”, or “No polygon”. | |
|
|
|
| |
| Fill Holes |
| Selects whether the programs fill in holes when importing the data. If the setting is “On”, the pro- | |
|
|
| gram will automatically generate points to fill in holes left by missing data. | |
|
|
|
| |
| Remove |
| Selects which the data the program excludes when carrying out the import. Select from an of the | |
|
|
| following: “None”, “Boundary (B.)”, “5deg. & B.”, “10deg. & B.”, “15deg. & B.”, or “20deg. & B.” | |
|
|
| None: | Removal is not carried out when importing the data. |
|
|
| Boundary(B.): | The program removes boundary points. |
|
|
| 5deg. & B.,10deg. & B., 15deg. & B., 20deg. & B.: | |
|
|
|
| The program removes boundary points, and also removes polygons within the |
|
|
|
| specified angular range (5°, 10 °, 15°, or 20°) to the view vector |
|
|
|
| |
| Filter |
| None: The program does not perform filtering when importing the data. | |
|
|
| Noise Filter (N.F.): When importing the data, the points that appear to be noise will be corrected | |
|
|
|
| according to other data. |
|
|
| High Quality (H.Q.): The program filters out unreliable data. (Effective only when importing data | |
|
|
|
| that was scanned using the VIVID 910.) |
|
|
| H.Q & N.F.: | Applies both noise filter and high quality filter. (Effective only when importing |
|
|
|
| data that was scanned using the VIVID 910.) |
|
|
|
| |
| Save CDM |
| Save the images as camera data. | |
|
|
|
|
|
910
900