File – Import – Digitizer – One Scan (When VIVID 910 is Selected)

Chapter 2

File

Menu

910

Parameters for [File-Import-Digitizer-One Scan] Dialog Box

AF

Executes auto-focus.

 

Note

 

 

This parameter is effective only when VIVID 910 is connected.

 

 

Distance

Checking this checkbox enables distance setting.

 

Note

 

 

This parameter is effective only when VIVID 910 is connected.

 

 

Intensity

Checking this checkbox enables LD and Gain setting.

 

• LD :

Sets the laser power.

 

• Gain :

Sets the gain.

 

Note

 

 

This parameter is effective only when VIVID 910 is connected.

 

 

Scan

Performs a scan.

 

Note

 

 

This parameter is effective only when VIVID 910 is connected.

 

 

Import CDM

Import the saved CDM data.

 

 

Color Read

Takes a color shot. Clicking this button at the end of scan will take a color shot again and display

 

the updated color image.

 

Note

 

 

This button is effective if the [Use Color] checkbox is checked.

 

 

Edit

Clicking this checkbox enables you to delete the area that is not necessary for threedimensionaliza-

 

tion by specifying it in the Work window area using the mouse.

 

 

Auto Store

If this checkbox is checked, data save will be performed automatically when corresponding points

 

are designated in the Work and Store window areas.

 

 

Store

Registers the data present in the Work window area as store data, puts it into three-dimensional

 

form and displays it in the element view window.

 

 

Mono/Color/Pitch

Switches display mode for the data currently displayed in the Work window area.

 

• Mono : The current image is displayed in monochrome. This parameter is effective only when

 

 

VIVID 9i is connected.

 

• Color : The color data acquired from the scan is displayed.

 

• Pitch : The color display is done in accordance with the distance data from Near to Far.

 

 

Angle

Rotates the rotary stage to the desired angle using the slide bar.

 

This item is displayed when the rotary stage has been initialized successfully.

 

 

Prev/Next

Switches from one stored data to another.

 

[Prev] button : Displays the previous data.

 

[Next] button : Displays the next data.

 

 

Delete

Deletes the stored data currently displayed in the Work or Store window area. The corresponding

 

elements in the element view window are also deleted at the same time.

 

 

View

Displays/hides the data currently displayed in the Store window area into the element view window.

 

 

OK

Keeps the element data created during command execution and exits the File-Import-Digitizer-

 

One Scan command.

 

Note

 

 

If the [Save Raw Data] checkbox is checked, the data save dialog box is displayed.

 

 

Cancel

Exits the File-Import-Digitizer-One Scan command.

 

The element data created during command execution will be deleted.

 

 

Option

Displays the [File-Import-Digitizer-One Scan-Option] dialogbox.

 

 

 

56