File – Import – Digitizer – One Scan (When VIVID 9i is Selected)
| 3 | Set an object in place. |
|
| If you are going to use the rotating stage, |
|
| place the object on it. |
| 4 | To display the object in the middle of |
|
| the Work window area, change the po- |
|
| sition of the object or move the instru- |
|
| ment back and forth to change the view |
|
| angle. |
|
|
|
Chapter 2 | 5 | Click the [Option] button. |
File |
|
Menu | The |
| |
| dialog box will appear. |
6 Set optional parameters.
Item | Explanation |
|
|
Scan Parameter | Sets the settings for scanning. |
|
|
Convert Parameter | Sets the settings for three- |
| dimensionalization. |
Stage Parameter | Select the rotary stage to be |
| used. |
[Default] button | Clicking this restores the |
| default settings. |
Ref. For details, refer to parameters (P.39) for
9i
7 After necessary settings are made, click the [OK] button.
The settings will be set and the
Memo
If necessary, replace the lens attached to the instrument. If the lenses are changed, carry out field calibration using the Field Calibration System.
•Select the desired stage in [Stage Parameter] field, and click on the [Apply] button. If the stage has been recognized properly, a stage slide bar will be displayed at the bottom of the work window when the
•If initialization is not successful, turn off the power to the rotary stage power, turn it on again, and then click on the [Apply] button.
34