Fill Holes
Remove
Hardware Parameter
Stage Parameter
Rotation Step
Default
OK
Cancel
Reduction Rate
Filter
Convert Parameter
Save Raw Data
Dark
Brightness
Use Color
Log
Dynamic Range Expan- sion Mode
Used to select the number of data points to be read from “1/1”, “1/4”, “1/9”, “1/16” and “No Polygon”.
Checking this checkbox displays the data save dialog at the end of the File-Import-Digitizer- Step Scan command, allowing you to save the data.
Performs dark correction for the color data if this checkbox is checked. This correction is used when lines are noticeable in the color image.
Checking this checkbox enables you to set the brightness of the image.
Checking this checkbox takes a color shot when a scan is made.
Performs log correction for the color data if this checkbox is checked. This correction is used to make neutral colors brighter.
If this button is checked, the program takes multiple shots so as to expand the dynamic range and reduce data loss. This button is displayed only for the VIVID 910.
• Save:
Loads the setting parameters from VIVID 910 and uses them as parameters for this command.
Saves the parameters set by this command to VIVID 910 as the setting parameters.
• Load:
Select the scanning mode : FINE or FAST
Parameters for [File-Import-Digitizer-Stepscan-Option] Dialog Box
Scan Parameter
Mode
Scan Parameter
File – Import – Digitizer – Step Scan (When VIVID 910 is Selected)

Chapter 2

File

Menu

910

66

None :Performs no correction for points when reading data. This can be set for User mode only.

Noise Filter (N.F.) : Reduces noise in points when reading data.

High Quarity (H.Q.) :Deletes low-reliable data when reading data.

H.Q. & N.F. : Reduces noise in points and deletes low-reliable data when reading data.

If “ON” is selected, points are generated in the holes that were produced as a loss of data so that the holes are filled.

Select the data to be deleted when reading data.

None :Outputs the data without performing specific processing.

Boundary(B.): Outputs the data after deleting boundary points.

5deg & B./10dwg & B./15deg. & B./20deg & B.:

Outputs the data after deleting the points present inside and at the bound ary of the polygons that are angled within approximately 5, 10, 15 and 20 degrees to the vector of the line of view.

Vertical : Check this checkbox if using the VIVID unit in vertical orientation.

Horizontal : Check this checkbox if using the VIVID unit in horizontal orientation.

Note

After changing the setting orientation, the Calibration Chart data of the rotating stage must be acquired again before measuring.

Select the Port and Model to be used and click the [Apply] button. The rotary stage will be initialized. If initialization is successful, the rotary stage can be controlled in the [File-Import- Digitizer-Step Scan] dialog box.

Select rotating angle for each step of rotary stage.

Restores the default parameter settings.

Closes the [File-Import-Digitizer-Step Scan-Option] dialog box.

The settings will be set.

Closes the [File-Import-Digitizer-Step Scan-Option] dialog box.

The settings will be cancelled.