8 Click the [OK] button.

The next specified angle will appear in [Current angle], and the object will be scanned for the next image.

If a rotating stage has been selected by the Turn- table, the stage will turn to the next angle and then the object will be scanned.

9 Repeat step 8 until shots from all the desired angles are captured.

When shots from all the desired angles are captured, the “Scan the chart ? The turntable will be move.” message dialog box will appear.

Click the [OK] button. The rotating stage will start to rotate toward the angle (home position) where the calibration chart is to be measured.

When the rotating stage has reached that angle

(home position), the “Scanning the Calibration

Chart.” message dialog box will appear.

Click the [OK] button. The rotating stage will start to rotate toward the angle (home position) where the calibration chart is to be measured.

When the rotating stage has reached that angle

(home position), the “Scanning the Calibration

Chart.” message dialog box will appear.

File – Import – Digitizer – Step Scan (When VIVID 900/910 is Selected)

Memo

In the range image, areas comprised of regular data are shown in color.

In High Quality mode, data for which laser intensity was too high are displayed in bright gray, while data for which intensity was too low are displayed in dark gray.

If the color and range images are not scanned at the same time, clicking the [Color Read] button or double-clicking on the image will capture a color image and display it.

• Dragging the mouse on the color image will en-

 

large the image. If necessary, enable color correc-

Chapter 2

tion such as “Dark”, “Log” and “Smooth”, in the

File

[Camera1] tab and load the color image again.

Menu

 

If the type of rotating stage has not been desig- nated, turn the rotating stage manually to the next angle displayed in the “Next angle:∗∗ degree” message dialog box.

To cancel scan, click the [Cancel] button instead of the [OK] button, and repeat steps 6 to 8.

Note

The rotating stage may rotate in the opposite direction during measurement depending on its type.

If you want to acquire a shot again, click the [Cancel] button to close the dialog box, click the angle cur- rently displayed in [Current] with the left mouse but- ton, then select the desired angle among those which have been set from the pulldown menu that appears.

 

 

 

 

 

Memo

 

 

If an angle (rotation step) has been selected at step 4,

 

necessary steps (angles) to complete 360 degrees will

910

900

be displayed in the pull-down menu. However, it is not

 

necessary to scan at all the angles. You can select neces-

 

sary steps (angles) only.

 

81