Build – Fill Holes – Auto

Filling Holes Automatically

This command is to create polygon data automatically for the holes (i.e. areas where no data is present) located in the area selected in the currently displayed element. However, some complicated holes may not be filled.

Operating Procedure

Chapter 2

Build

Menu

1

From the element list, select one desired

 

element.

2 Select the points on the boundary of the hole for which you want to create polygon data.

3 From the [Build] menu, select [Fill Holes] and then click [Auto].

The system will search for holes present within the area of the selected points. A bar will be displayed during search to indicate progress. If a hole is found, only the points on its boundary will be selected.

If no holes are found, a message dialog box will appear. Clicking the [OK] button will close the dialog box and exit the menu.

All the element view windows will be hidden, and the temporary window and [Build-Fill Holes-Auto] dialog box will appear.

The hole for which you want to create polygon data will be displayed in the temporary window. The points comprising the hole will be highlight- ed (yellow). The selected holes will be processed one by one, starting with the hole composed of the largest number of points.

Note

It is not possible to close the temporary window.

Memo

If the number of remaining holes (Number of holes) is 1, the [OK] button will be displayed instead of the [Next Hole] button.

9i

910

900

700

300

4 Set the [Flatness] and [Algorithm] pa- rameters, and click the [Apply] button.

The program merges the elements to create a new element. The new element is given the name that you just entered.

A progress bar shows the progress while the fill is being carried out. If you click the progress bar’s [Cancel] button, the program suspends fill processing and displays a dialog showing results up to that moment.

Memo

The program retains the fill data generated up to the time when you clicked the [Cancel] button. If you wish to resume the fill operation, click the [All] button. Filling will then continue from the hole at which the operation was suspended.