DS33Z41 Quad IMUX Ethernet Mapper
Register Name: |
|
| GL.IMXCN |
|
|
|
|
| ||
Register Description: |
| Inverse MUX Configuration Register |
|
|
| |||||
Register Address: |
| 16h |
|
|
|
|
| |||
Bit # | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | ||
Name |
| — | T1E1 |
| RXE | SENDE | L4 | L3 | L2 | L1 |
Default |
| 0 | 0 |
| 0 | 0 | 0 | 0 | 0 | 0 |
Bit 6: T1E1 Mode (T1E1). This bit determines if IMUX if for T1 or E1 Mode. 0 = T1 Mode
1 = E1 Mode
Bit 5: Receive Enable (RXE). If this bit is set to 1, data will be received from the Serial Interface and passed to the packet processor. If equal to 0, no data will be sent to the packet processor.
Bit 4: SEND Enable (SENDE). If this bit is set to 1, the data will be transmitted on the Serial Interface. If equal to 0, data is blocked.
Bit 3: Link 4 (L4). If this bit is set to 1, link number four is participating in the communication. If this bit is equal to 0, the link does not participate.
Bit 2: Link 3 (L3). If this bit is set to 1, link number three is participating in the communication. If this bit is equal to 0, the link does not participate.
Bit 1: Link 2 (L2). If this bit is set to 1, link number two is participating in the communication. If this bit is equal to 0, the link does not participate.
Bit 0: Link 1 (L1). If this bit is set to 1, link number one is participating in the communication. If this bit is equal to 0, the link does not participate.
Register Name: | GL.IMXC |
|
|
|
|
| |||
Register Description: | Inverse MUX Command Register |
|
|
| |||||
Register Address: | 17h |
|
|
|
|
|
| ||
Bit # | 7 | 6 |
| 5 | 4 | 3 | 2 | 1 | 0 |
Name | IMUXC7 | IMUXC6 |
| IMUXC5 | IMUXC4 | IMUXC3 | IMUXC2 | IMUXC1 | IMUXC0 |
Default | 1 | 1 |
| 1 | 1 | 1 | 1 | 1 | 1 |
Bits 0 to 7: Inverse Multiplexing Command (IMUXC[0:7]). This byte is used to issue IMUX commands.
AVAILABLE USER COMMANDS
VALUE | COMMAND | COMMENT |
|
|
|
1111 1111b | NOP | No operation to perform. |
|
|
|
1000 0010b | Link Start | Establish Link with the distant end. Upon reception of this message, |
this distant end begins searching for 3 consecutive sequence | ||
|
| numbers. |
|
|
|
The user must send a link start command. The NOP command may be written to this register after the link start command is written. All values other than those listed above will be ignored.
74 of 167