DS33Z41 Quad IMUX Ethernet Mapper

Register Name:

 

 

GL.IMXCN

 

 

 

 

 

Register Description:

 

Inverse MUX Configuration Register

 

 

 

Register Address:

 

16h

 

 

 

 

 

Bit #

7

6

5

4

3

2

1

0

Name

 

T1E1

 

RXE

SENDE

L4

L3

L2

L1

Default

 

0

0

 

0

0

0

0

0

0

Bit 6: T1E1 Mode (T1E1). This bit determines if IMUX if for T1 or E1 Mode. 0 = T1 Mode

1 = E1 Mode

Bit 5: Receive Enable (RXE). If this bit is set to 1, data will be received from the Serial Interface and passed to the packet processor. If equal to 0, no data will be sent to the packet processor.

Bit 4: SEND Enable (SENDE). If this bit is set to 1, the data will be transmitted on the Serial Interface. If equal to 0, data is blocked.

Bit 3: Link 4 (L4). If this bit is set to 1, link number four is participating in the communication. If this bit is equal to 0, the link does not participate.

Bit 2: Link 3 (L3). If this bit is set to 1, link number three is participating in the communication. If this bit is equal to 0, the link does not participate.

Bit 1: Link 2 (L2). If this bit is set to 1, link number two is participating in the communication. If this bit is equal to 0, the link does not participate.

Bit 0: Link 1 (L1). If this bit is set to 1, link number one is participating in the communication. If this bit is equal to 0, the link does not participate.

Register Name:

GL.IMXC

 

 

 

 

 

Register Description:

Inverse MUX Command Register

 

 

 

Register Address:

17h

 

 

 

 

 

 

Bit #

7

6

 

5

4

3

2

1

0

Name

IMUXC7

IMUXC6

 

IMUXC5

IMUXC4

IMUXC3

IMUXC2

IMUXC1

IMUXC0

Default

1

1

 

1

1

1

1

1

1

Bits 0 to 7: Inverse Multiplexing Command (IMUXC[0:7]). This byte is used to issue IMUX commands.

AVAILABLE USER COMMANDS

VALUE

COMMAND

COMMENT

 

 

 

1111 1111b

NOP

No operation to perform.

 

 

 

1000 0010b

Link Start

Establish Link with the distant end. Upon reception of this message,

this distant end begins searching for 3 consecutive sequence

 

 

numbers.

 

 

 

The user must send a link start command. The NOP command may be written to this register after the link start command is written. All values other than those listed above will be ignored.