Displaying PoE configuration using the CLI 165

Figure 53

show poe-main-status command output

ATTENTION

The Power Source Present listing displays the current power source for the switch: AC Only.

show poe-port-status command

The show poe-port-statuscommand displays the status, power status, power limit, and port priority of each port. The syntax for the show poe-port-statuscommand is:

show poe-port-status [port <portlist>]

The show poe-port-statuscommand is executed in the User Exec command mode.

The DTE Power Status displays error messages if the port is not providing power. The following messages can appear:

Detecting—port detecting IP device requesting power

Delivering power—port delivering requested power to device

Invalid PD—port detecting device that is not valid to request power

Deny low priority—power disabled from port because of port setting and demands on power budget

Overload—power disabled from port because port is overloaded

Test—port in testing mode

Error—none of the other conditions apply

Table 40 "show poe-port-status command parameters and variables" (page

166)describes the parameters and variables for the show poe-port-status command.

Nortel Ethernet Routing Switch 2500 Series

Overview — System Configuration

NN47215-500 (323162-B) 02.02 Standard

4.1 19 November 2007

Copyright © 2007, Nortel Networks

Page 165
Image 165
Nortel Networks 2500 Series manual Show poe-port-status command parameters and variables