Configuring PoE port parameters using the CLI 161

"poe poe-shutdown command" (page 161)

"poe poe-priority command" (page 162)

"poe poe-limit command" (page 163)

no poe-shutdown command

The no poe-shutdowncommand enables power to the port. The syntax for the no poe-shutdowncommand is:

no poe-shutdown [port <portlist>]

The no poe-shutdowncommand is executed in the Interface Configuration command mode.

Table 36 "no poe-shutdown command parameters and variables" (page

161)describes the parameters and variables for the no poe-shutdown command.

Table 36

no poe-shutdown command parameters and variables

Parameters and

Description

variables

 

 

 

port <portlist>

Enter the port numbers on which you want to enable

 

 

power.

 

The default value is enabled.

ATTENTION

If you omit this parameter, the system uses the port entered with the interface FastEthernet command.

poe poe-shutdown command

The poe poe-shutdowncommand disables power to the port. The syntax for the poe poe-shutdowncommand is:

poe poe-shutdown [port <portlist>]

The poe poe-shutdowncommand is executed in the Interface Configuration command mode.

Nortel Ethernet Routing Switch 2500 Series

Overview — System Configuration

NN47215-500 (323162-B) 02.02 Standard

4.1 19 November 2007

Copyright © 2007, Nortel Networks

Page 161
Image 161
Nortel Networks 2500 Series manual No poe-shutdown command, Poe poe-shutdown command