1.1 Incoming Call Features

1.1.2.2Internal Call Block

Description

Internal calls can be restricted on a COS basis. Each COS of the caller can enable or disable this feature for each COS of the called party.

[Programming Example]

Called Party

Caller

COS 1 COS 2 COS 3

...

COS 1

COS 2

COS 3

:

:

:

:

:

: Block

Explanation:

a)COS 1 can make calls to all extensions.

b)COS 2 can make calls to COS 1 only. (COS 2 cannot make calls to COS 2.)

c)COS 3 can make calls to COS 3 only.

COS 1

Extn. 100

Extn. 101

COS 2

 

 

 

COS 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extn. 102

Extn. 103

Extn. 104

Extn. 105

Extn. 106

Conditions

Restricted extension numbers cannot be the parameter of the feature settings (e.g., Walking Extension).