C O M M A N D L I N E I N T E R F A C
.E
|
| . |
|
| Commands |
|
| . . . |
OUTPUT | The table below lists all DGy 201x output commands, their arguments | |
. . . . . . . . . | and detailed descriptions. | |
COMMANDS |
|
|
Table |
| |
|
|
|
Command | Arguments | Description |
GAMma | <0.5...2.0> | Sets the playback gamma. |
|
| Default: 1.0 |
|
|
|
OUTPUT | (none) | A query command which returns information on the |
|
| current output timing. |
OutPutTiMingLOAD | <1..160> | Sets the output raster to the timing selected from |
|
| the Timing List. In order to load the output timing |
|
| parameters the DGy 201x must be in the FreeRun |
|
| mode. |
|
| (see OutputMode) |
|
| Refer to Factory Timing List, page 118 for details. |
|
|
|
OutPutTiMingNAME | <name> | Assigns a name to the current output timing. The |
|
| argument can be up to 23 alphanumeric characters |
|
| with no spaces (underscore is acceptable). |
OutPutTiMingSAVE | <100..160> | Saves the timing data of the current output raster |
|
| into the Timing List. The argument specifies which |
|
| Timing List position is used. |
|
| If OutPutTiMingSAVE is issued for an already |
|
| occupied position, the DGy requests overwrite |
|
| confirmation. |
|
| Refer to the Factory Timing List section for |
|
| additional details. |
OutPutTiMing | <hfp> <hs> <hbp> | Sets the timing for the current output. |
| <hact> <vfp> <vs> |
|
| <vbp> <vact> <hfreq> |
|
| <sync> <hpol> <vpol> |
|
| <il> |
|
OutPutTiMing | <HFP HS HBP | Changes (or reports) one parameter of the current |
(Alternate) | HACT VFP VS VBP | output timing. |
VACT HFREQ SYNC |
| |
|
| |
| HPOL VPOL |
|
| IL>[<value>] |
|
| DGy Model 201x User’s Guide | 98 |