INTRODUCTION
DGy A/V Inputs and Outputs
350-9047 v3.0.1 DGy Model 201x User’s Guide 4
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DGy A/V INPUTS AND OUTPUTS
The DGy 201x includes a comprehensive array of inputs and outputs
enabling the recording, playing, and streaming of low data-rate signals
— all the way to high resolution graphic displays.
. . . . . . . . .
SYSTEM INPUTS The following system inputs are provided:
Digital — One digital input is provided (DVI-I integrated
digital/analog connector). With a pixel rate up to 165 MHz, this
input supports a resolution of up to 1600 x 1200 at 60 Hz, or
higher refresh rates at lower resolutions.
RGB — One analog RGB input is provided (DVI-I integrated
digital/analog connector). With a pixel rate up to 330 MHz, this
input supports a resolution of up to 1600 x 1200 at 60 Hz, or
higher refresh rates at lower resolutions.
Stereo Audio — One analog stereo input is provided (2 x RCA
phono connectors). Sampling rate may be set to 44.1 kHz,
22.05 kHz or 11.025 kHz.
IRIG Timecode (optional) - A looping input compatible with
IRIG-B DCLS and 1KHz modulated formats (IRIG B123) can be
used to synchronize the system time clock to an external IRIG
time standard. The loop output is used to pass the IRIG-B input
signal to another IRIG-compatible device.
. . . . . . . . .
SYSTEM OUTPUTS The following system outputs are provided:
Digital/RGB — A DVI-I integrated digital/analog connector
supports a resolution of 1600 x 1200 at 60Hz.
Loop — Both the analog and digital graphics inputs have an
active loop. The input signal is output on the loop connector,
when the DGy 201x is powered on.
Stereo Audio — One analog stereo output is provided (2 x RCA
phono connectors).
In Appendix A, refer to the DVI-I Connector section for complete wiring
details on the DVI-I connector.