O P E R A T I O N. . Options Window ..

.

The DGy Control Panel will lose communication with the DGy 201x as soon as the restart procedure begins. If the IP address of the DGy 201x has been changed, the new network settings must be used to reconnect to it. After the connection has been dropped, the WCP or Telnet session must be restarted.

S E R I A L P O R T S E T T I N G S

The current serial port baud rate is displayed and can be changed in this section of the Systems tab. Available baud rates range from 9600 baud to 115,200 baud. It is recommended that the default baud rate, 115k baud, be used. To change the serial port parameters:

~Use the pull-down Baud Rate menu to set the baud rate for the system’s RS-232 serial port. The default value is 115,200 baud.

~Check the Echo On box to enable echo.

C L O C K S E T T I N G S

The DGy 201x uses an internal real-time clock to time stamp the recordings.

The DGy system time and date can be set manually or synchronized to the PC controlling the DGy 201x.

In the Clock section:

~Click Sync to PC to load the PC’s local time into the DGy 201x’s temporary clock register.

~Use the Date and Time up/down selectors to adjust the date and time as necessary.

~Identify the Time Zone the DGy 201x is located in by using the drop down Time Zone box.

~Click Apply to upload the new time setting into DGy 201x’s active clock register.

OR

~Specify the time zone the DGy 201x is in by using the drop down Time Zone box.

~Use the entry boxes to manually set the Date and Time.

~Click Apply to upload the new time setting into DGy 201x active clock register.

When Apply is clicked, a Restart Warning is displayed. (Figure 3-20.) Click No to cancel the reboot and go back to the old time and date values; click Yes to restart the DGy 201x using the time and date values. A