OPERATION
Options Window
350-9047 v3.0.1 DGy Model 201x User’s Guide 55
. . . . .
The DGy Control Panel will lose communication with the DGy
201x as soon as the restart procedure begins. If the IP address
of the DGy 201x has been changed, the new network settings
must be used to reconnect to it. After the connection has been
dropped, the WCP or Telnet session must be restarted.
SERIAL PORT SETTINGS
The current serial port baud rate is displayed and can be
changed in this section of the Systems tab. Available baud
rates range from 9600 baud to 115,200 baud. It is
recommended that the default baud rate, 115k baud, be used.
To change the serial port parameters:
~Use the pull-down Baud Rate menu to set the baud rate
for the system’s RS-232 serial port. The default value is
115,200 baud.
~Check the Echo On box to enable echo.
CLOCK SETTINGS
The DGy 201x uses an internal real-time clock to time stamp the
recordings.
The DGy system time and date can be set manually or
synchronized to the PC controlling the DGy 201x.
In the Clock section:
~Click Sync to PC to load the PC’s local time into the DGy
201x’s temporary clock register.
~Use the Date and Time up/down selectors to adjust the
date and time as necessary.
~Identify the Time Zone the DGy 201x is located in by
using the drop down Time Zone box.
~Click Apply to upload the new time setting into DGy
201x’s active clock register.
OR
~Specify the time zone the DGy 201x is in by using the
drop down Time Zone box.
~Use the entry boxes to manually set the Date and Time.
~Click Apply to upload the new time setting into DGy
201x active clock register.
When Apply is clicked, a Restart Warning is displayed.
(Figure 3-20.) Click No to cancel the reboot and go
back to the old time and date values; click Yes to restart
the DGy 201x using the time and date values. A