C O M M A N D L I N E I N T E R F A C

.E

 

 

 

 

.

 

 

 

 

Commands

 

 

 

 

. . .

MISCELLANEOUS

The table below lists all DGy 201x miscellaneous commands, their

. . . . . . . . .

arguments and detailed descriptions.

COMMANDS

 

 

 

 

Table 6-10Miscellaneous Commands

 

 

 

 

 

 

Command

 

Arguments

Description

Help

 

[<command>]

Help, without an argument will display the entire

 

 

 

serial command set. Help, with a command as an

 

 

 

argument will display detailed information about

 

 

 

that command.

ID

 

(none)

Displays the following DGy information:

 

 

 

Product type

 

 

 

Date of manufacture

 

 

 

Serial number

 

 

 

Firmware version number

 

 

 

Input type

VERsion

 

(none)

Displays the following DGy information:

 

 

 

Firmware version

 

 

 

FPGA version number,

 

 

 

Web Control Panel (WCP) version

 

 

 

 

number.

BAUDrate

 

<9600 19200

Sets the serial port baud rate. Operation of the

 

 

38400 57600

serial port at the highest possible speed is

 

 

115200>

recommended.

 

 

 

Default: 115,200

 

 

 

 

ECHO

 

<ON OFF>

Turns the serial echo On/Off. The echo is only on

 

 

 

commands typed and sent to the unit.

 

 

 

Note: The Echo setting has no effect on responses

 

 

 

issued by the DGy; responses are always visible,

 

 

 

regardless of the Echo status.

 

 

 

Default: ON

 

 

 

 

HANDShaking

 

<HardWare

Sets the type of flow control on the serial port.

 

 

SoftWare>

The HardWare handshaking uses CTS/RTS

 

 

 

 

 

 

control.

 

 

 

 

The SoftWare handshaking protocol is XON-XOFF.

 

 

 

Default: SoftWare

 

 

 

 

HOSTNAME

 

<hostname>

Sets Ethernet hostname.

 

 

 

Default: DGy

 

 

 

 

 

350-9047 v3.0.1

DGy Model 201x User’s Guide

115