C O M M A N D L I N E I N T E R F A C

.E

 

 

.

 

 

Commands

 

 

. . .

Table 6-9Time Commands (Continued)

 

 

 

 

Command

Arguments

Description

RealTimeClockSYNC

<OFF IRIG

The internal DGy real time clock can be

 

NetworkTimeServer>

automatically synchronized to an external

 

 

network time server. When the RTCSYNC is

 

 

set to OFF, the DGy internal clock is not

 

 

synchronized to an external time reference

 

 

(IRIG or NTS).

 

 

When the RTCSYNC is set to

 

 

NetworkTimeServer the DGy will automatically

 

 

synchronize its internal clock to the network

 

 

time server first specified by the NTSIP

 

 

command. Note that when using the NTSIP to

 

 

display your local time correctly, you must set

 

 

the Time Zone to correspond with your

 

 

geographical location.

 

 

Note: DGy requires a full time Internet

 

 

connection to provide this capability. See also:

 

 

NTSIP and TimeZone.

 

 

When the RTCSYNC is set to IRIG, the DGy

 

 

will automatically synchronize it’s internal clock

 

 

to the external (optional) IRIG time reference

 

 

connected to the IRIG input (see also

 

 

IRIGSTandarD).

 

 

Default: OFF

 

 

 

RealTimeClockSYNCPERiod

[30 ... 1440]

Sets the update interval period for the NTS or

 

 

(optional) IRIG reference time servers. The

 

 

period is set in minutes, 30 to 1440 minutes in

 

 

30 minute intervals.

 

 

Default: 120

 

 

 