COMMAND LINE INTERFACE
Commands
350-9047 v3.0.1 DGy Model 201x User’s Guide 114
. . . . .
RealTimeClockSYNC <OFF | IRIG |
NetworkTimeServer> The internal DGy real time clock can be
automatically synchronized to an external
network time server. When the RTCSYNC is
set to OFF, the DGy internal clock is not
synchronized to an external time reference
(IRIG or NTS).
When the RTCSYNC is set to
NetworkTimeServer the DGy will automatically
synchronize its internal clock to the network
time server first specified by the NTSIP
command. Note that when using the NTSIP to
display your local time correctly, you must set
the Time Zone to correspond with your
geographical location.
Note: DGy requires a full time Internet
connection to provide this capability. See also:
NTSIP and TimeZone.
When the RTCSYNC is set to IRIG, the DGy
will automatically synchronize it’s internal clock
to the external (optional) IRIG time reference
connected to the IRIG input (see also
IRIGSTandarD).
Default: OFF
R
eal
T
ime
C
lock
SYNCPER
iod
[30 ... 1440] Sets the update interval period for the NTS or
(optional) IRIG reference time servers. The
period is set in minutes, 30 to 1440 minutes in
30 minute intervals.
Default: 120
Table 6-9 Time Commands (Continued)
Command Arguments Description