C O M M A N D L I N E I N T E R F A C
.E
|
| . |
|
| Commands |
|
| . . . |
Table |
| |
|
|
|
Command | Arguments | Description |
TiMingLIST | [<1..160> [<1..160>]] | Displays the list of saved input and output timings. |
| [ACTIVE] | If two numeric arguments are supplied, displays all |
|
| entries in the range. ACTIVE, displays only the |
|
| active timings. |
TiMingLISTCLEAR | (none) | Deletes all user entries from the Timing List. |
|
|
|
TiMingLISTLOAD | <100 ...160> <name> | This command is used to create and save a user |
| <hfp> <hs> <hbp> | timing set to the Timing List. |
| <hact> <vfp> <vs> | User defined entries may be saved to the list using |
| <vbp> <vact> <hfreq> | |
| slots 100 - 160. Timing slots 1 - 99 are reserved for | |
| <sync> <hpol> <vpol> | |
| factory defined timing settings. | |
| <il> | |
|
| |
|
| The name parameter is a name that is used to |
|
| identify the timing set (for example mytiming3). |
|
| hfp - width of the horizontal front porch (pixels) |
|
| hs - width of the horizontal sync pulse (pixels) |
|
| hbp - width of horizontal back porch (pixels) |
|
| hact - width of the active picture area (pixels) |
|
| vfp - width of the vertical front porch (pixels) |
|
| vs - width of the vertical sync pulse (pixels) |
|
| vbp - width of vertical back porch (pixels) |
|
| vact - height of the active picture area (pixels) |
|
| hfreq - horizontal frequency (Hz) |
|
| sync - type of sync signal (analog 3, 4 or 5 wire) |
|
| hpol - polarity of horizontal sync pulse (0=negative, |
|
| 1=positive) |
|
| vpol - polarity of vertical sync pulse (0= negative, |
|
| 1=positive) |
|
| il - interlace (0 = non interlace, 1 = interlace) |
|
|
|
| DGy Model 201x User’s Guide | 95 |