Avaya P332G-ML manual Rmon alarm Command

Models: P332G-ML

1 242
Download 242 pages 24.77 Kb
Page 134
Image 134

Chapter 5

CLI – Layer 2

 

 

interval

The interval between 2 samples.

number of

The number of buckets defined

buckets

 

owner name

Owner name string

Example:

P330-N# rmon history 1026 1026 3/2 30 buckets 20 owner amir

history 1026 was created successfully

Note: If you wish to define a name which includes spaces, you must enclose the entire name in quotation marks, e.g. "new york".

Rmon alarm Command

Use the rmon alarm command to create a new RMON alarm entry.

The syntax for this command is:

rmon alarm <Alarm Number> <variable> <interval> <sampletype> rising-threshold<rising threshold> <rising event> falling- threshold <falling threshold> <falling event> <startup alarm>

<owner>

 

alarm number

This is the alarm index number of this entry (it is advisable to

 

use the same interface number as your alarm index number.)

variable

This is the MIB variable which will be sampled by the alarm

 

entry.

interval

The interval between 2 samples

sample type

This can be set to either delta (the difference between 2

 

samples) or an absolute value.

rising threshold

This sets the upper threshold for the alarm entry.

rising event

The RMON event entry that will be notified if the upper

 

threshold is passed.

falling

This sets the lower threshold for the alarm entry.

threshold

 

116

P332G-ML User’s Guide

Page 134
Image 134