Chapter 4 Installation and Setup
Powering On – P332G-ML Module AC
For the AC input version of the
If you are using a BUPS, insert a power cord from the
Caution: Ensure that you connect your
After power up or reset, the
Powering On – P332G-ML Module DC
For the DC input version of the
1Connect the power cable to the switch at the input terminal block. Note that:
—The terminals are marked “+”,
—The size of the three screws in the terminal block is M3.5.
—The pitch between each screw is 9.5mm.
Warning: Before performing any of the following procedures, ensure that DC power is OFF.
Caution: This product is intended for installation in restricted access areas and is approved for use with 18 AWG copper conductors only. The installation must comply with all applicable codes.
2 Connect the power cable to the DC power supply.
Warning: The proper wiring sequence is ground to ground, positive to positive and negative to negative. Always connect the ground wire first and disconnect it last.
After power up or reset, the
31 |