Bose MR-J2S- B Indication list, Operation And Display, 2.** indicates the warning/alarm No

Models: MR-J2S- B

1 172
Download 172 pages 5.2 Kb
Page 68
Image 68
(2) Indication list

4. OPERATION AND DISPLAY

(2) Indication list

Indication

Status

 

 

Description

 

 

AA

Initializing

The servo amplifier was switched on when power to the servo system

 

controller is off.

 

 

 

 

 

 

 

 

 

 

 

 

Power to the servo system controller was switched off during power-on of

 

 

 

the servo amplifier.

 

 

 

 

 

The axis No. set to the servo system controller does not match the axis No.

 

Ab

Initializing

set with the axis setting switch (CS1) of the servo amplifier.

 

 

A servo amplifier fault occurred or an error took place in communication

 

 

 

 

 

 

with the servo system controller. In this case, the indication changes:

 

 

 

 

"Ab" "AC"

"Ad"

"Ab"

 

 

 

 

The servo system controller is faulty.

 

 

AC

Initializing

Communication

started

between the servo system controller and

servo

 

amplifier.

 

 

 

 

 

 

 

 

 

 

Ad

Initializing

The initial parameters from the servo system controller were received.

 

 

AE

Initialize completion

Initial data communication with the servo system controller was completed.

(Note 1)

b#

Ready OFF

The ready off signal from the servo system controller was received.

 

(Note 1)

d#

Servo ON

The ready off signal from the servo system controller was received.

 

(Note 1)

C#

Servo OFF

The ready off signal from the servo system controller was received.

 

(Note 2)

**

Alarm Warning

The alarm No./warning No. that occurred is displayed. (Refer to Section 9.1.)

 

88

CPU error

 

 

 

 

(Note 3)

b0.

 

JOG operation,

positioning operation, programmed operation, DO

forced

 

output.

 

 

 

 

 

(Note 3)

 

 

 

(Note 1)

b#.

 

 

 

 

Test operation mode

 

 

 

 

 

d#.

Motor-less operation

 

 

 

 

 

 

 

c#.

 

 

 

 

 

Note: 1. # denotes any of numerals 0 to 8 and what it means is listed below:

#

Description

0

Set to the test operation mode.

1

First axis

2

Second axis

3

Third axis

4

Fourth axis

5

Fifth axis

6

Sixth axis

7

Seventh axis

8

Eighth axis

2.** indicates the warning/alarm No.

3.Requires the servo configuration software.

4 - 5

Page 68
Image 68