11. CHARACTERISTICS

Use the dynamic brake at the load inertia moment indicated in the following table. If the load inertia moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility that the load inertia moment may exceed the value, contact Mitsubishi.

Servo amplifier

Load inertia moment ratio [times]

MR-J2S-10B to MR-J2S-200B

30

MR-J2S-10B1 to MR-J2S-40B1

 

MR-J2S-350B

16

MR-J2S-500B

15

MR-J2S-700B

 

11.4 Encoder cable flexing life

The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed values, provide a little allowance for these values.

Flexing life [times]

1108

5107

1 107

5 106

1 106

5 105

1 105

5 104

1 104

5 103

1 103

4

a

a : Long flexing-life encoder cable

MR-JCCBLM-H

MR-JHSCBLM-H

MR-ENCBLM-H

b : Standard encoder cable

MR-JCCBLM-L

MR-JHSCBLM-L

b

7

10

20

40

70

100

200

 

 

Flexing radius [mm]

 

 

11 - 7