5.PARAMETERS
5.PARAMETERS
CAUTION | Never adjust or change the parameter values extremely as it will make operation | |
instable. | ||
|
POINT
When the servo amplifier is connected with the servo system controller, the parameters are set to the values of the servo system controller. Switching power off, then on makes the values set on the servo configuration software invalid and the servo system controller values valid.
In the maker setting parameters, do not set any values other than the initial values.
Setting may not be made to some parameters and ranges depending on the model or version of the servo system controller. For details, refer to the servo system controller user's manual.
5.1 Parameter write inhibit
POINT
When setting the parameter values from the servo system controller, the parameter No. 40 setting need not be changed.
In this servo amplifier, the parameters are classified into the basic parameters (No. 1 to 11), adjustment parameters (No. 12 to 26) and expansion parameters (No. 27 to 40) according to their safety aspects and frequencies of use. The values of the basic parameters may be set/changed by the customer, but those of the adjustment and expansion parameters cannot. When
The following table indicates the parameters which are enabled for reference and write by parameter No. 40 setting.
Setting | Operation | Operation from controller | Operation from servo configuration | |
0000(initial value) | Reference | Parameter No.1 to 39 | Parameter No.1 to 11 40 | |
Write | ||||
|
|
| ||
000A | Reference | Parameter No.1 to 39 | Parameter No.40 | |
Write | ||||
|
|
| ||
000C | Reference | Parameter No.1 to 39 | Parameter No.1 to 40 | |
Write | Parameter No.1 to 11 40 | |||
|
| |||
000E | Reference | Parameter No.1 to 39 | Parameter No.1 to 40 | |
Write | ||||
|
|
| ||
100E | Reference | Parameter No.1 to 39 | Parameter No.1 to 40 | |
Write | Parameter No.40 | |||
|
|
5.2 Lists
POINT
For any parameter whose symbol is preceded by*, set the parameter value and switch power off once, then switch it on again to make that parameter setting valid.
5 - 1