Bose MR-J2S- B instruction manual Signals And Wiring

Models: MR-J2S- B

1 172
Download 172 pages 5.2 Kb
Page 62
Image 62
Manual background

3. SIGNALS AND WIRING

3.11 Control axis selection

POINT

The control axis number set to CS1 should be the same as the one set to the servo system controller.

Use the axis select switch (CS1) to set the control axis number for the servo. If the same numbers are set to different control axes in a single communication system, the system will not operate properly. The control axes may be set independently of the bus cable connection sequence.

Set the switch to "F" when executing the test operation mode using servo configuration software.

Axis select switch (CS1)

6

7

 

5 4

3

2 1

8

9

 

 

 

 

A

 

 

B

 

 

C

 

 

D

 

F

E

0

 

 

 

No.

Description

0

Axis 1

1

Axis 2

2

Axis 3

3

Axis 4

4

Axis 5

5

Axis 6

6

Axis 7

7

Axis 8

8

Not used

9

Not used

A

Not used

B

Not used

C

Not used

D

Not used

E

Not used

F

Test operation mode or

 

when machine analyzer is used

 

(Refer to Section 6.1.2)

3 - 25

Page 62
Image 62
Bose MR-J2S- B instruction manual Signals And Wiring